01913J - Triton RFA-12-A95-BAX-A15 19 armoire murale 3-en-1, 1265HE, hauteur 835 mm,noir
- Rupture de stock
01913J
01913J - Triton RFA-12-A95-BAX-A15 19 armoire murale 3-en-1, 1265HE, hauteur 835 mm,noir
RFA-wall cabinetone-piece 19" wall-cabinet with protection class IP20three separate 19"-sections1st section: The first section allows the installation of 19" components with a max. height of 6U and a depth of 450 mm. They are installed vertically, the 19" rails in the cabinet are depth adjustable. Cable entries with breakout panels are located in the rear wall, the roof and the bottom.2nd Section: In the second section a mounting width of 19", a height of 12U and a depth of 450mm are available. The mounting rails are fully adjustable. Here are usually structured cabling as well as the active elements of the company´s network concentrated and the individual services are allocated to the recommended up to 48 jobs (each with 2 ports as per standard).3rd section: The third section includes the entire surface of the bottom of the housing. Here is space for components with a maximum depth of 800 mm, a width of 19" and a height of 2 to 7U, depending on the housing type. Access to this section is through the door on the right side. Besides the cabinet has to be enough distance for the extraction of components.The cabinet is mounted directly to the wallPart of the cabinet are two sliding adjustable positions respectively vertical mounting rails in each sectionCabinet construction: welded frame, door combination for different sections: 4mm thick tempered glass (also full sheet metal or perforated door is possible) and perforated doorThe maximum permissible load of the individual doors is 10 kgThe cabinets are intended for installation of data and telecommunication devices and their distribution systemsThe frame of the cabinet and all the removable parts are connected with earthing cables that have to be properly fixed and inserted during the lifetime of the cabinetIn the bottom of the cabinet there is a M8 screw as the main earthing pointCable openings covered with breakout panels are at the top and bottom of the rear wall, and in the top and bottom and the central partition wall between the sectionsIn the first section of the door there are openings (you can break out) for the installation of fansmaximum height of the server: 5UOPERATING CONDITIONSOfficesThe cabinet is not intended for outdoor use or under conditions that may have a negative influence on its function and the installed components (e.g. environment with danger of explosion or humid and wet rooms)It is to protect against:- mechanical damageother than the intended use for the cabineta false treatment means in particular:- Overloading (exceeding the recommended maximum load)- Installation of equipment that may affect the operation and functioning of the cabinet or the installed components negatively- Intervention in the cabinet construction and its design
Aucun avis n'a été publié pour le moment.
Votre avis ne peut pas être envoyé